Deterministic modeling of API5L X52 steel in a coal-tar-coating/cathodic-protection system in soil

2016 
Abstract Impedance characteristic signal for a coal tar-coated API5L-X52 steel with cathodic protection has been investigated in soil using electrochemical impedance spectroscopy (EIS). Deterministic transmission line model (TLM) has been set up to simulate the impedance results of pipeline with intact and artificial defect coating, and to verify the damage evolution of coated pipeline with cathodic protection in soil. To illustrate the coating inherent property, coating in each transmission line unit has been assumed to be represent by two imaginary parts: a relatively coating barrier part which serves as parallel of capacitor and resistor (C per R per ); and another part considered as porous coating serves as parallel of porous coating and double layer (C por R por (C dl R ct )). The parameter θ has been proposed to calculate the total impedance of the coating, to illustrate its performance. An adjustment was applied to calculate total resistance R t mathematically, based on the simulation results to illustrate the damage evolution concept. The R t values are in agreement with the proposed damage evolution stages.