4D flow MRI versus conventional 2D for measuring pulmonary flow after Tetralogy of Fallot repair

2019 
Abstract Background After tetralogy of Fallot (TOF) repair, pulmonary regurgitation and right ventricular function must be monitored. Conventional (2D) cardiac magnetic resonance (CMR) is currently the clinical reference method for measuring pulmonary regurgitation. However, 4DFlow CMR has been reported to provide a more comprehensive flow analysis than 2D CMR. We aimed to compare 4DFlow CMR to 2D CMR for assessing pulmonary regurgitation and flow, as well as aortic flow, in children and adults after surgical repair of TOF. Methods Retrospective analysis of patients with repaired TOF admitted for cardiac MRI with 4DFlow acquisition from 2016 to 2018. Linear regression was used to assess correlations and Bland-Altman analyses were performed. Results The 60 included patients had a mean age of 18.2 ± 10.4 years (range, 2–54 years). Significant correlations between the two techniques were found for pulmonary regurgitant fraction (R [2] = 0.6642, p  Conclusion These results establish the feasibility and reliability of 4DFlow CMR for assessing pulmonary flow in a large paediatric and adult population with repaired TOF. 4DFlow CMR may be more reliable than 2D MRI for pulmonary flow assessment after TOF repair.