Standard TLP with 100ns pulse width often fail to reproduce anomalous ESD failures in products. However multi-level TLP based on the advanced hardware modifications and settings is capable of reproducing many such failures, hence significantly improving ESD troubleshooting. Representative case studies confirm the usefulness of this technique.