Efficacy of Spacers in Radiation Therapy for Locally Advanced Pancreatic Cancer: A Planning Study.

2021 
BACKGROUND/AIM We aimed to investigate the dosimetric effects of a spacer placed between the pancreas and surrounding gastrointestinal structures in intensity-modulated radiation therapy (IMRT) planning to provide more effective radiation therapy for locally advanced pancreatic cancer (LAPC). PATIENTS AND METHODS Treatment planning was performed for six patients with LAPC based on computed tomography images without spacers and with 5-mm or 10-mm spacers virtually inserted under the supervision of a hepatobiliary pancreatic surgeon. The prescription dose was 63 Gy in 28 fractions. RESULTS With the exception of one case of pancreatic head cancer, planning target volume receiving ≥95% of the prescribed dose (PTV V95) was achieved by 90% or more by inserting a spacer, and by 95% or more in all 3 cases of pancreatic body and tail cancer by inserting a 10-mm spacer. CONCLUSION IMRT with appropriate spacer placement may help provide high-dose treatment for LAPC and improve associated patient outcomes.
    • Correction