Emittance measurement and modeling for the Fermilab Booster

2007 
We systematically measured the emittance evolution of a fast cycling proton accelerator on a turn-by-turn basis under various beam intensities via an ionization profile monitor (IPM). The vertical emittance growth rate was derived and phenomenologically analyzed. The transverse and longitudinal components in the horizontal beam size were separated by making use of their different evolution behaviors. The quadrupole mode beam size oscillation after transition crossing is also studied and explained. We found a considerable space-charge-induced emittance growth rate component in the vertical plane but not as much for the horizontal plane. We carried out multiparticle simulations to understand the mechanism of space-charge-induced emittance growth. The major sources of emittance growth were found to be the random skew-quadrupole and dipole field errors in the presence of large space-charge tune spread.