A Modified Apparatus for Dual, Sterilized, Isolated Perfusion of the Rat Liver

1990 
The isolated perfused rat liver (IPRL) has proven to be a useful model for the study of physiology and pathology of the liver. For research in nonparenchymal cell (NPC) function that includes measurement of cytokine production (eg, TNF), it is necessary to have a sterilized perfusion system. We have modified the IPRL apparatus so as to be able to perform sterile perfusions of two livers simultaneously. The perfusion apparatus is a recirculating closed system in which the oxygenator is a plastic container separated into two chambers by a fenestrated plastic wall. A disposable macropore filter functions as both a bubble trap and perfusate filter. The sterilization process is done by immersing the various components in Benz-All solution. The tubing is disinfected by irrigation with 10% Clorox followed by 0.9% sodium chloride solution. The perfusate used is filter-sterilized Krebs buffer solution containing 0.5 g Mandol/250 mL perfusate. Not only can two organs be conveniently perfused simultaneously, but the...
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    7
    References
    0
    Citations
    NaN
    KQI
    []