Influência da função pulmonar e da força muscularna capacidade funcional de portadores de doençapulmonar obstrutiva crónica = The influence of lung function and muscular strength on the functional capacity of chronic obstructive pulmonary disease patients

2009 
Objectivo : Determinar que variavel entre o volume expirado forcado no primeiro segundo (VEF1), a pressao parcial do oxigenio no sangue arterial (PaO2), a hipoxemia nocturna e a forca muscular do quadricipite femoral pode predizer a distância percorrida no teste de caminhada de seis minutos (TC6) em doentes com DPOC. Doentes e metodos : Um estudo observacional do tipo transversal, envolvendo trinta doentes encaminhados a um programa de reabilitacao pulmonar de um hospital universitario. A funcao pulmonar foi avaliada por espirometria, gasometria arterial e oximetria nocturna. A funcao muscular pela forca muscular do quadricipite femoral e a avaliacao da capacidade funcional pelo TC6. Resultados : A analise de regressao bivariada mostrou que a forca do quadricipite femoral foi a unica varia- vel que se mostrou estatisticamente significativa (p = 0,002) em predizer a distância, sendo responsa- vel por 38% da variância do TC6. Para essas variaveis a relacao estabelecida estatisticamente foi que para cada quilo de forca do quadricipite femoral, os doentes caminharam 5,9 metros no TC6. Conclusao : Os resultados indicam a importância da forca muscular do MI em testes de esforco submaximo. Entre as variaveis estudadas, apenas a forca muscular do quadricipite femoral pode predizer a distância percorrida no TC6 em portadores de doenca pulmonar obstrutiva cronica. Aim : To determine which variable (forced expiratory volume in 1 second (FEV1), partial pressure of oxygen in arterial blood (PaO2), nocturnal hypoxaemia and muscular strength of femoral quadriceps) can predict the distance walked in the six-minute walk test (6MWT) by COPD patients. Methods : A cross-sectional and observational study of thirty patients referred to a pulmonary rehabilita tion programme at a university hospital. Lung function was evaluated by spirometry, arterial blood gas analysis and nocturnal oximetry. Muscle function was evaluated by quadriceps strength and functional capacity by the 6MWT. Results : Bivariate regression analysis showed that quadriceps strength, was the only variable to correlate significantly with the distance walked in the 6MWT (p=0.002), accounting for 38% of the 6MWT variance. The statistical relationship established for these variables was 1kg of quadriceps strength equalled 5.9 metres walked in the 6MWT. Conclusions : Our results showed the importance of lower limb muscle strength in submaximal exercise testing. We conclude that femoral quadriceps muscle strength is the only one of the variables studied which can predict the distance COPD patients walk in the 6MWT.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    0
    References
    0
    Citations
    NaN
    KQI
    []