Three-dimensional dose evaluation system using real-time wind field information for nuclear accidents in Taiwan

2006 
In Taiwan, the three operating nuclear power plants are all built along the coast over complex terrain. Dose estimates after a nuclear accident with releases of radioactive materials, therefore, cannot be accurately calculated using simple dispersion models. We developed a three-dimensional dose evaluation system, which incorporates real-time prognostic wind field information with three-dimensional numerical models to predict dose results. The proposed system consists of three models: a three-dimensional mesoscale atmospheric model (HOTMAC), a three-dimensional transport and diffusion model (RAPTAD), and a dose calculation model (DOSE). The whole-body dose and thyroid dose as well as dose rates can be rapidly estimated and displayed on the three-dimensional terrain model constructed by satellite images. The developed three-dimensional dose evaluation system could accurately forecast the dose results and has been used in the annual nuclear emergency response exercise to provide suggestions for protective measures.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    13
    References
    9
    Citations
    NaN
    KQI
    []