Prognostic implications of serial outpatient blood pressure measurements in patients with an axial continuous-flow left ventricular assist device

2019 
BACKGROUND Elevated blood pressure (BP) has been linked to adverse events during left ventricular assist device support. In this study we investigated the association between outpatient BP and stroke or suspected pump thrombosis among HeartMate II (HMII) recipients. METHODS We retrospectively studied 220 HMII patients. Serial outpatient BP measurements were averaged. Patients were categorized by: (1) mean arterial pressure (MAP), high (>90 mm Hg) vs intermediate (80 mm Hg ≤ MAP ≤ 90 mm Hg) vs low ( RESULTS The risk for the primary end-point was increased in the high MAP group (adjusted hazard ratio [HR] 2.75, 95% confidence interval [CI] 1.49 to 5.05, vs intermediate MAP; and 6.73, 1.9 to 23.9, vs low MAP). MAP had higher predictive value for the primary end-point compared with SBP ( p  = 0.05). Patients with high SBP had a higher rate of stroke (HR 2.8, 95% CI 1.09 to 7.17, vs low SBP). The combination of high SBP and low PP was associated with the highest risk for stroke. The lowest quartile of visit-to-visit MAP variability was associated with the highest risk for the primary end-point. CONCLUSIONS Elevated outpatient BP is associated with increased risk for stroke or suspected pump thrombosis in HMII recipients. Reduced PP and low visit-to-visit BP variability may confer additional risk.