Radiometric modeling through the combined use of the EDR gamma scanner and the VISIPLAN dose assessment tool

2004 
Abstract In this paper, we present the work performed on the integration of a new gamma scanner prototype, known as EDR, with a 3D-dose assessment software tool called VISIPLAN. It is one of the first approaches to merge gamma imaging instrumentation and a 3D-dose assessment program into a combined operative hardware–software solution for the characterization of a site in the field of radiation protection. The main features of the scanner design are presented here, together with a representative part of the tests performed during its characterization. The EDR directional sensitivity is determined for two gamma radiation fields originating from 137 Cs and 60 Co sources and forms the basis for the interpretation of the gamma scans using VISIPLAN. The combination of a 3D-source model and the detailed instrument response function can determine the source activities from the gamma scans, and also enables in a second step, the simulation of the dose-rate field on the site. The integration of the two tools was tested in a laboratory and validated in an industrial facility.