Test-retest reliability of knee extensor rate of velocity and power development in older adults using the isotonic mode on a Biodex System 3 dynamometer
2018
Isotonic testing and measures of rapid power production are emerging as functionally relevant test methods for detection of muscle aging. Our objective was to assess reliability of rapid velocity and power measures in older adults using the isotonic mode of an isokinetic dynamometer. Sixty-three participants (aged 65 to 82 years) underwent a test-retest protocol with one week time interval. Isotonic knee extension tests were performed at four different loads: 0%, 25%, 50% and 75% of maximal isometric strength. Peak velocity (pV) and power (pP) were determined as the highest values of the velocity and power curve. Rate of velocity (RVD) and power development (RPD) were calculated as the linear slopes of the velocity- and power-time curve. Relative and absolute measures of test-retest reliability were analyzed using intraclass correlation coefficients (ICC), standard error of measurement (SEM) and Bland-Altman analyses. Overall, reliability was high for pV, pP, RVD and RPD at 0%, 25% and 50% load (ICC: .85 - .98, SEM: 3% - 10%). A trend for increased reliability at lower loads seemed apparent. The tests at 75% load led to range of motion failure and should be avoided. In addition, results demonstrated that caution is advised when interpreting early phase results (first 50ms). To conclude, our results support the use of the isotonic mode of an isokinetic dynamometer for testing rapid power and velocity characteristics in older adults, which is of high clinical relevance given that these muscle characteristics are emerging as the primary outcomes for preventive and rehabilitative interventions in aging research.
Keywords:
- Correction
- Source
- Cite
- Save
- Machine Reading By IdeaReader
46
References
12
Citations
NaN
KQI