Development and Validation of Analytical Methods for Picoxystrobin Determination in Agricultural Products by GC-ECD and GC-MS

2012 
A simple and sensitive analytical method was developed using gas chromatography with electron capture detector (GC-ECD) and gas chromatography-mass spectrometry (GC-MS) for determination of Picoxystrobin in agricultural products (apple, hulled rice, mushroom, pepper, soybean, and mandarin). Picoxystrobin residues were extracted with acetonitrile, partitioned with saline water, and then they were cleaned up on a florisil solid-phase extraction (SPE) cartridge to obtain an extract suitable for analysis by GC-ECD and GC-MS. The method was validated using 6 agricultural product samples spiked with Picoxystrobin at different concentration levels (0.02, 0.05 and 0.5 mg/L). Average recoveries of Picoxystrobin (using each concentration three replicates) ranged 64.0~98.3% with relative standard deviations less than 10%, calibration solutions concentration in the range 0.1~5 mg/L, and limit of detection (LOD) and limit of quantification (LOQ) were 0.005 and 0.02 mg/L, respectively. The result showed that the developed analytical method is suitable for Picoxystrobin determination in agricultural products.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    10
    References
    1
    Citations
    NaN
    KQI
    []