A rapid and sensitive loop-mediated isothermal amplification procedure (LAMP) for Mycoplasma hyopneumoniae detection based on the p36 gene

2015 
The aim of this study was to establish a method for sensitive and rapid diagnosis of Mycoplasma hyopneumoniae in clinical specimens. To this effect, we employed three sets of primers specifically designed for amplification of nucleic acids under isothermal conditions. After optimization of reaction conditions, M. hyopneumoniae could be successfully detected at 63°C in 45 min through use of the loop-
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    20
    References
    4
    Citations
    NaN
    KQI
    []