Monoclonal Antibody-Based Lateral Flow Assay for Detection of Botulinum Neurotoxin Type A

2008 
ABSTRACT A rapid lateral flow assay was developed to detect botulinum neurotoxin type A (BoNT/A). The assay was based on the sandwich format using monoclonal antibodies (MAbs) of two distinct specificities. One anti-BoNT/A heavy chain MAb (150-3) was immobilized to a defined detection zone on a porous nitrocellulose membrane, while the other anti-BoNT/A heavy chain MAb (44.1) was conjugated to colloidal gold particles, which served as a detection reagent. The BoNT/A-containing sample was added to the strip and allowed to react with MAb (44.1)-coated particles. The mixture was then passed along the porous membrane by capillary action past the MAb (150-3) in the detection zone, which binds the particles that had BoNT/A bound to their surface, giving a red color within this detection zone with intensity proportional to BoNT/A concentration. In the absence of BoNT/A, no immunogold was bound to the solid-phase antibody. With this method, 50 ng/mL of BoNT/A were detected in less than 10 min. The assay sensitivi...