Terahertz calorimetry for the Herschel Space Observatory

2004 
Terahertz laser calorimetry has been employed to measure the emissivity of samples of the Herschel telescope mirror at T=77 K, and the absorptivity of absorbers meant for the PACS and HIFI instruments at T=10 K. As a spin-off, a simple broadband absolute power meter has been developed.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    2
    References
    0
    Citations
    NaN