Improved complex filter applied in enhancing EFT/B immunity at a coal mine monitoring substation

2008 
A monitoring system is an important guarantee of safety in a production mine. However, not all monitoring substations pass the electrical fast transient/burst (EFT/B) immunity test and the explosion-proof test simultaneously. To enhance the immunity, the values of capacitance and inductance should be increased, which are actually limited by coal mine explosion-proof standards. Hence, for the first time, an active filter was applied in an electromagnetic interference (EMI) output filter. As a result, the interference within 30 MHz clearly weakened, but the frequency spectrum had a wide range. An EMI input filter and ferrite beads were adopted to restrain higher frequency interference. An output interference spectrogram of the substation was obtained with an analyzer. The results indicate that the improved complex filtering markedly help to control interference. With the support of improved complex filtering and other enhancing immunity means about I/O ports, the substation managed to pass both the EFT/B immunity test and the explosion-proof test synchronously. We conclude that improved complex filtering is of vital importance in enhancing the electromagnetic compatibility (EMC) of the coal mine monitoring system.