Abstract We demonstrate NDIR CO2 gas sensing using CMOS compatible MEMS ScAlN-based pyroelectric detectors. The ScAlN-based pyroelectric detectors are fabricated using 8-inch wafer level technology with 12 % Sc-doped AlN deposited at a temperature of ∼200 °C. Together with a blackbody thermal emitter, a 10 cm long enclosed gas channel with only inlet and outlet holes connected to tubings, and testing using 2 different reference gases (N2 and synthetic air), measurements show voltage signal drop due to CO2 gas absorption at the 4.26 μm wavelength at CO2 gas concentrations ranging from 5000 ppm down to 25 ppm. The signal change due to the CO2 gas response ranges from ∼2% at 100 ppm CO2 concentration to ∼40 % at 5000 ppm CO2 gas concentration for both CO2 gas measured in N2 and in synthetic air. CO2 gas response times are also measured for CO2 gas in N2 and in synthetic air at concentrations of 5000 ppm, 1000 ppm and 400 ppm. The gas response times measured around 2 s and lower. Introduction of humidity show some minor effect (