Chemical composition of selected core samples, Idaho National Engineering Laboratory, Idaho

1995 
This report presents chemical compositions determined from 84 subsamples and 5 quality-assurance split subsamples of basalt core from the eastern Snake River Plain. The 84 subsamples were collected at selected depths from 5 coreholes located on the Idaho National Engineering Laboratory, Idaho. This report was jointly prepared by Lockheed Idaho Technologies Company and the U.S. Geological Survey, in cooperation with the U.S. Department of Energy, Idaho Operations Office. Ten major elements and as many as 32 trace elements were determined for each subsample either by wavelength dispersive X-ray fluorescence spectrometry, inductively coupled plasma mass spectrometry, or by both methods. Descriptive statistics for each element were calculated and tabulated by analytical method for each corehole.