Modification of Metoclopramide GLC Assay: Application to Human Biological Specimens

1979 
A modified electron-capture GLC assay for metoclopramide in human biological specimens is reported. This assay involves the incorporation of a back-extraction method to remove endogenous contaminants. Its applicability was demonstrated by studying the time course of metoclopramide in plasma and urine from a human subject. The lowest quantifiable metoclopramide concentration in plasma was 7 ng/ml, provided 0.5 ml of plasma was used.