2019 
Film boiling heat transfer coefficients were measured for the test wires of 0.5 and 0.7 mm in diameters and 200mm in length located at the centre of 8 mm diameter conduit with upward flow of liquid hydrogen. Pressures are ranged from 0.4 to 1.1 MPa, liquid subcoolings from 0 to 11 K and flow velocities up to 5 m/s. The experimental data were compared with the authors' correlation for forced flow film boiling already presented based on the data for 1.2 mm diameter test wire. The experimental data are higher than the predicted values by the correlation. Discussion is made on the effect of wire diameter observed and a new correlation was presented.