Radioactive gas and hydrogen removal after a LOCE at the LOFT Facility

1979 
The use of a silver-zeolite halogen adsorber placed in series with a hydrogen catalytic recombiner and a cryogenic noble gas adsorber assembly constitutes a waste gas processing system (WGPS) capable of handling hydrogen and fission product gases following a Loss-of-Coolant Experiment (LOCE). This paper describes: the types and quantities of gases expected to be found at the facility after a failed-fuel LOCE; the purpose of the WGPS; and the general configuration and expected decontamination factors associated with the LOFT WGPS.