Appropriate column configurations for the rapid analysis and semipreparative purification of the radiolabeled drug flutamide by high-performance liquid chromatography

2001 
Flutamide, marketed as Eulexin, is used for treatment of metastic prostatic carcinoma. Purity of a radiolabeled batch for metabolism studies was first determined by reversed-phase HPLC on a 5 μm, 150×4.6 mm analytical column. The separation was then scaled up to give a semipreparative column (5 μm, 250×10 mm) purification procedure. Fraction analysis was done on a short rapid analysis (5 μm, 50×3.0 mm) column. Analysis of the final product was performed on the analytical column. All columns were YMC-Pack ODS-AQ. The analytical work involved large mass injections in order to have the required amounts of radioactivity needed for accurate impurity profile determinations, and the preparative work involved masses much larger than the calculated scale-up values. Ultraviolet and radiochromatograms of the drug on the various column configurations are compared. A 95.7% recovery of product was obtained, with radiochemical purity increased from 95.0 to 99.8%.