Absorbable Polydioxanone (PDS) suture provides fewer wound complications than polyester (ethibond) suture in acute Tendo-Achilles rupture repair
2017
: We prospectively studied acute Achilles tendon rupture in patients over a two 2-year period and reviewed the causes, outcome and complications. There were 53 patients included with acute Achilles rupture with minimum follow up period of 6 months. We compared the outcomes including infection rate and Boyden score between the two groups repaired by Polydioxanone and Polyester respectively. All infected cases had a suture repair using the polyester suture. The difference in the infection rate was highly significant between the 2 groups (p=0.001). All 34 patients (100%) in the PDS group had good / excellent results based on the Boyden clinical assessment. Conversely, only 16 patients 9(68.4%) had good or excellent results IN Polyester repair group. Patients treated with a non- absorbable suture (ethibond) material for repair had a higher incidence infection and worse Boyden scores than the absorbable PDS group.