Induction Motor Broken Rotor Bar Detection Based on Rotor Flux Angle Monitoring

2019 
This paper presents a method for the detection of broken rotor bars in an induction motor. After introducing a simplified dynamic model of an induction motor with broken cage bars in a rotor field reference frame which allows for observation of its internal states, a fault detection algorithm is proposed. Two different motor estimation models are used, and the difference between their rotor flux angles is extracted. A particular frequency component in this signal appears only in the case of broken rotor bars. Consequently, the proposed algorithm is robust enough to load oscillations and/or machine temperature change, and also indicates the fault severity. The method has been verified at different operating points by simulations as well as experimentally. The fault detection is reliable even in cases where traditional methods give ambiguous verdicts.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    36
    References
    11
    Citations
    NaN
    KQI
    []