The Development of an Environmental Surveillance Protocol to Detect Candida auris and Measure the Adequacy of Discharge Room Cleaning Performed by Different Methods

2020 
Background: Contaminated surfaces within patient rooms and on shared equipment is a major driver of healthcare-acquired infections (HAIs). The emergence of Candida auris in the New York City metropolitan area, a multidrug-resistant fungus with extended environmental viability, has made a standardized assessment of cleaning protocols even more urgent for our multihospital academic health system. We therefore sought to create an environmental surveillance protocol to detect C. auris and to assess patient room contamination after discharge cleaning by different chemicals and methods, including touch-free application using an electrostatic sprayer. Surfaces disinfected using touch-free methods may not appear disinfected when assessed by fluorescent tracer dye or ATP bioluminescent assay. Methods: We focused on surfaces within the patient zone which are touched by the patient or healthcare personnel prior to contact with the patient. Our protocol sampled the over-bed table, call button, oxygen meter, privacy curtain, and bed frame using nylon-flocked swabs dipped in nonbacteriostatic sterile saline. We swabbed a 36-cm2 surface area on each sample location shortly after the room was disinfected, immediately inoculated the swab on a blood agar 5% TSA plate, and then incubated the plate for 24 hours at 36°C. The contamination with common environmental bacteria was calculated as CFU per plate over swabbed surface area and a cutoff of 2.5 CFU/cm2 was used to determine whether a surface passed inspection. Limited data exist on acceptable microbial limits for healthcare settings, but the aforementioned cutoff has been used in food preparation. Results: Over a year-long period, terminal cleaning had an overall fail rate of 6.5% for 413 surfaces swabbed. We used the protocol to compare the normal application of either peracetic acid/hydrogen peroxide or bleach using microfiber cloths to a new method using sodium dichloroisocyanurate (NaDCC) applied with microfiber cloths and electrostatic sprayers. The normal protocol had a fail rate of 9%, and NaDCC had a failure rate of 2.5%. The oxygen meter had the highest normal method failure rate (18.2%), whereas the curtain had the highest NaDCC method failure rate (11%). In addition, we swabbed 7 rooms previously occupied by C. auris–colonized patients for C. auris contamination of environmental surfaces, including the mobile medical equipment of the 4 patient care units that contained these rooms. We did not find any C. auris, and we continue data collection. Conclusions: A systematic environmental surveillance system is critical for healthcare systems to assess touch-free disinfection and identify MDRO contamination of surfaces. Funding: None Disclosures: None
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    0
    References
    0
    Citations
    NaN
    KQI
    []