Experimentally studying TV3-117 gas-turbine unit characteristics at superheated water injection into a compressor

2014 
The results from experimentally studying TV3-117 gas-turbine unit (GTU) characteristics at injection of cold and superheated (metastable) water to the inlet of the GTU compressor are presented. In the latter case, the finer water atomization is obtained. The water injection makes it possible to considerably increase the unit power. At a constant temperature of the working fluid downstream of the turbine combustion chamber, water injection in an amount of 1% of the air flow rate provides an increase in the turbine power by approximately 12% and expands GTU controlling potentialities. The use of the metastable superheated water atomization enables one to more reliably implement the technology of water injection into a compressor, especially into intermediate compressor stages. However, it requires accounting for operational conditions of particular installation. Due to small water droplet residence time in the compressor flow path, even with fine water atomization, in aircraft engine derivative power turbines, about 15–20% of moisture injected have no time to completely evaporate within the compressor. When injecting cold water, this figure is from 5 to 10% larger.