Radiation emission dose from patients administered 90 Y-labelled radiopharmaceuticals: comparison of

2008 
Results A good correlation was found between the Monte Carlo simulation test and the ionization chamber detector results: the air kerma dose rate was 4.2±0.1 and 4.4±0.8lGy/h, respectively (r=0.9, P<0.01). Moreover, more than 99.7% of the air kerma dose rate measured with the ionization chamber detector was because of the contribution of electrons, whereas the contribution of photons was less than 0.3%. In contrast, the air kerma dose rate measured with the crystal NaI(Tl) detector was significantly lower (0.76+0.12lGy/h) in comparison with the Monte Carlo simulation test. This underestimation was related to the limited crystal NaI(Tl) detector response to low energy rates at variance with the ionization chamber detector. The effective radiation dose released by patients treated with 90 Y-labelled tiuxetan to parents and the