Abstract P4-08-25: Decentralized beta testing of MammaPrint and BluePrint NGS kit at University Hospitals Leuven and Curie Institute Paris

2019 
Background Many countries restrict patient material exchange to central diagnostic laboratories abroad, limiting access to assays like MammaPrint ® (MP) and BluePrint ® (BP). Both assays are microarray-based, with MP being prognostic for distant recurrence and BP for molecular subtyping of breast cancer (Luminal-, HER2-, and Basal-type). To increase accessibility, decentralization is required with Next Generation Sequencing (NGS) being the preferred testing platform given that most diagnostic laboratories have the technology in place. The aim of this beta testing study is to validate a previously developed and centrally validated MP and BP NGS kit for RNA samples in two large tertiary academic hospitals in Europe. Patients and Methods Patients with early breast cancer diagnosed at the Multidisciplinary Breast Center at University Hospitals Leuven and Curie Institute Paris were prospectively included between September 2017 and January 2018. Patients with bilateral breast cancer or presenting with more than 3 positive lymph nodes were excluded. Only patients with invasive ductal and invasive lobular carcinoma were included. Twenty tissue sections were cut from formalin-fixed, paraffin-embedded (FFPE) blocks; 10 tissue sections were analyzed at the local site using the MP and BP NGS kit, and 10 tissue sections were analyzed at Agendia using the same kit and procedure, as well as with the golden standard method (gene expression microarrays). Targeted RNA sequencing of the 70 MP and 80 BP signature genes was performed on Illumina MiSeq instruments. The raw NGS data generated at the local test sites was sent through a secure file transfer protocol server to Agendia for interpretation and comparison with microarray and NGS performed in the Agendia laboratories. We aimed for a minimum concordance rate between MP and BP outcome of 90% between each local site and Agendia9s centralized site. Results In this study, 116 early breast cancer patients were included (73 from University Hospitals Leuven and 43 from Curie Institute). Out of these patients, 52% were MP Low Risk and 48% MP High Risk according to microarray. The patients had a BP luminal, HER2 or basal subtype in respectively 83%, 9% and 8%. Concordance between MP microarray obtained from Agendia and MP NGS obtained from the local sites was 91.4%. Concordance between MP High and Low Risk classification between NGS Leuven versus NGS Agendia was 92.1% and between NGS Curie versus NGS Agendia 95.3%. For BP subtype outcomes, the results from microarray versus NGS for all patients combined from both local sites gave a 98.3% concordance and NGS Agendia versus NGS from each local site gave a 100% concordance. Conclusion The MP and BP NGS kit was successfully validated in a decentralized setting, showing high concordance between results obtained at three different sites. There was a clear benefit of having well-trained NGS experienced diagnostic technical teams. The MP and BP NGS kit the first FFPE targeted RNA sequencing based multigene signature for breast cancer care, will provide a high and equal standard of MP and BP gene expression testing for breast cancer in a decentralized setting. Citation Format: Slembrouck L, Laurent C, Delahaye LJ, Mittempergher L, Vanden Bempt I, Vander Borght S, Darrigues L, Vliegen L, Sintubin P, Raynal V, Bohec M, Reyes C, Rapinat A, Helsmoortel C, Jongen L, Hoste G, Neven P, Wildiers H, Smeets A, Nevelsteen I, Punie K, Van Nieuwenhuysen E, Han S, Salomon AV, Faron EL, Cynober T, Witteveen AT, Neijenhuis S, Glas AM, Reyal F, Floris G. Decentralized beta testing of MammaPrint and BluePrint NGS kit at University Hospitals Leuven and Curie Institute Paris [abstract]. In: Proceedings of the 2018 San Antonio Breast Cancer Symposium; 2018 Dec 4-8; San Antonio, TX. Philadelphia (PA): AACR; Cancer Res 2019;79(4 Suppl):Abstract nr P4-08-25.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    0
    References
    0
    Citations
    NaN
    KQI
    []