A GM cryocooler with new cold helium circulation system has been developed at Cryomech. A set of check valves connects to the cold heat exchanger to convert a small portion of AC oscillating flow in the cold head to a DC gas flow for circulating cold helium in the remote loop. A cold finger, which is used for remote cooling, is connected to the check valves through a pair of 5 m long vacuum insulated flexible lines. The GM cryocooler, Cryomech model AL125 having 120 W at 80 K, is employed in the testing. The cold finger can provide 50 W at 81 K for the power input of 4.1 kW and 70.5 W at 81.8 K for the power input of 6 kW. This simple and low cost design is very attractive for some applications in the near future.