Sextupole magnets for the Fermilab Main Injector

1993 
A sextupole magnet has been designed to satisfy the dynamical, geometrical, and electrical requirements of the Fermilab Main Injector. The steel length is 0.457 m. The top and bottom pole tips are 26.4 mm from the center line. the side pole tips are 48.0 mm from the center line. The design integrated strength is 55 T-m/m/sup 2/ at 294 A. >