Predictors of Carotid Occlusion Intolerance During Proximal Protected Carotid Artery Stenting

2014 
Abstract Objectives The aim of this study was to identify predictors of occlusion intolerance (OI) developing during proximal protected carotid artery stenting (CAS). Background The use of proximal embolic protection devices, such as endovascular occlusion, during CAS has been demonstrated to be particularly safe and effective. However, endovascular occlusion can expose the ipsilateral hemisphere to hypoperfusion and produce transient neurological symptoms (OI). Methods From March 2010 to March 2012, 605 consecutive patients underwent proximal protected CAS at our institution. To identify independent predictors of OI, a multivariate logistic regression model was developed that included all patients’ clinical/angiographic and procedural characteristics. Results OI developed in a total of 184 patients (30.4%). Compared with patients in whom OI did not develop, those who experienced OI had lower occlusion pressure (OP) (42.3 ± 12.7 mm Hg vs. 61.9 ± 15.4 mm Hg, p  Conclusions OI may occur in as many as one-third of the patients undergoing proximal protected CAS. This event is more common in those patients with an OP ≤40 mm Hg. Patients presenting with concomitant occlusion of the contralateral internal carotid artery more frequently have an OP ≤40 mm Hg.