Posterior jaws rehabilitation with < 7mm-short implants. A review.

2021 
INTRODUCTION The results with shorter and shorter implants have been revolutionizing the implantology scenario and are worthy of being well-analyzed and understood. This review aims to add further knowledge about the last 10-years observation period on < 7mm-short implants in the posterior atrophic jaws, better defining the indication of their use. METHODS From a Medline database research, systematic reviews, controlled and no- controlled trials (CT, n-CT) with ≥ 3years-follow-ups on <7 mm / ≥ 5mm-short implants (group A), and clinical studies with ≥ 1year-follow-up on 4mm-short implants (group B) were considered. The outcomes, in terms of implant survival rate (SR), marginal bone loss (MBL), and complications were analyzed according to the duration of follow-ups, implant site (maxilla and mandible), type of prosthesis (single crown or splinted units), vertically impaired or normal sites. RESULTS Thirty-four trials (28 for group A and six for group B) were selected. Group A: a mean follow up of 5,8 (3-10) years came out; pre-and post-loading SR range was 94.4- 100% and 89.6-100%, respectively; the range of MBL was 0.12-1.49; 50% of CT found less statistically significant surgical complications in comparison with standard implants (ST) in reconstructed sites, while major prosthetic problems were recorded with short -implants (SH) in 37.5% of CT; in no atrophied sites, a mean SR range of 86.7-100 % vs. 88-100 % and a total bone loss of 2 vs.1.6 for SH vs.ST emerged. Group B: the overall mean follow-up period was 2,3 years, and the pre-and post- SR ranges were 93-100 % and 87.5-100 %, respectively. The MBL range was 0.02- 0.63 mm. All RCT reported significantly fewer surgical complications with SH than with ST in reconstructed mandibles within one year. No prosthetic complications were reported for up to 5 years using no pontics or cantilevers fixed bridges. CONCLUSIONS Similar or even better results for SH than ST in terms of post-loading SR and MBL came out for < 7mm/ ≥ 5mm-short implants in atrophic bone regardless of the prosthetic solutions, with less surgical complications but a few more prosthetic problems; the good results up to 5 years for 4mm-short implants in mandibles are associated with splinted and no-risk prosthetic solutions.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    114
    References
    0
    Citations
    NaN
    KQI
    []