Three-dimensional whole-brain mapping of cerebral blood volume and venous cerebral blood volume using Fourier transform-based velocity-selective pulse trains.

2021 
PURPOSE To develop 3D MRI methods for cerebral blood volume (CBV) and venous cerebral blood volume (vCBV) estimation with whole-brain coverage using Fourier transform-based velocity-selective (FT-VS) pulse trains. METHODS For CBV measurement, FT-VS saturation pulse trains were used to suppress static tissue, whereas CSF contamination was corrected voxel-by-voxel using a multi-readout acquisition and a fast CSF T2 scan. The vCBV mapping was achieved by inserting an arterial-nulling module that included a FT-VS inversion pulse train. Using these methods, CBV and vCBV maps were obtained on 6 healthy volunteers at 3 T. RESULTS The mean CBV and vCBV values in gray matter and white matter in different areas of the brain showed high correlation (r = 0.95 and P < .0001). The averaged CBV and vCBV values of the whole brain were 5.4 ± 0.6 mL/100 g and 2.5 ± 0.3 mL/100 g in gray matter, and 2.6 ± 0.5 mL/100 g and 1.5 ± 0.2 mL/100 g in white matter, respectively, comparable to the literature. CONCLUSION The feasibility of FT-VS-based CBV and vCBV estimation was demonstrated for 3D acquisition with large spatial coverage.