Closeout of IE Bulletin 84-02: Failures of General Electric Type HFA relays in use in Class 1E safety systems

1991 
Documentation is provided in this report to close IE Bulletin 84--02 regarding the failure of General Electric Type HFA relays in Class 1E safety systems. The relay failures were due to aging of coil wire insulation and nylon or Lexan spools under certain environmental conditions. The bulletin was issued to nuclear power reactor licensees and holders of construction permits to provide assurance that the manufacturer's recommendations for corrective actions would be implemented. The bulletin required four specific actions, plus a review of the general concerns of the bulletin even though some facilities had different relays from those of bulletin concern. Evaluation of utility responses, NRC/Region inspection reports, and regional telephone calls has resulted in bulletin closeout of 116 (98%) of the 118 facilities to which the bulletin was issued for action. Facilities which were shut down or had construction halted indefinitely or permanently when the report was issued are not included in this review. A follow-up item is proposed in Appendix C for the two facilities with open status. Background information is supplied in the Introduction and Appendix A.