Plasma Vitellogenin Levels during the Annual Reproductive Cycle of the Female Rainbow Trout (Oncorhynchus mykiss): Establishment and Validation of an ELISA
1997
Abstract Rainbow trout, Oncorhynchus mykiss , vitellogenin (Vtg) was purified from plasma of E 2 -treated male by direct anion exchange chromatography and some of its biochemical characteristics were studied. Our results demonstrated that, under SDS-PAGE conditions, rainbow trout Vtg was composed of two molecular forms of 390 and 176 kDa representing, respectively, the dimeric form and the monomeric form of the molecule. The purified Vtg was used to raise a polyclonal antibody for Vtg (anti-Vtg). Using this anti-Vtg, a competitive enzyme-linked immunosorbent assay (ELISA) was developed for the quantification of rainbow trout Vtg. The practical sensitivity range of this ELISA was 20–320 ng/ml (80–20% of binding) and the detection limit was 9 ng/ml. The intra- and the inter-assay coefficients of variation (at 50% of binding) were estimated at 1.8% (n = 10) and 3.9% (n = 13), respectively. This ELISA was validated by detecting changes in Vtg levels in rainbow trout at different physiological stages, as well as in 2-year-old female rainbow trout throughout the reproductive cycle.
Keywords:
- Correction
- Source
- Cite
- Save
- Machine Reading By IdeaReader
28
References
99
Citations
NaN
KQI