Waveguide interrogated optical immunosensor (WIOS) for detection of sulfonamide antibiotics in milk.

2009 
Abstract An immunosensor was developed for the detection of sulfonamide antibiotics in milk. Detection relied on a competitive immunoassay format, using immunoreagents previously developed for the generic detection of sulfonamide antibiotics and evaluated by enzyme-linked immunosorbent assay. The immunoassay was implemented onto a microsystem platform, the wavelength interrogated optical sensing device, which uses the evanescent field to probe changes at the interface of a waveguiding layer, and thus allows sensitive detection of biomolecule adsorption. The immunoreagents were immobilized onto the surface of the waveguide chip, and a fluidic cell allowed flowing analyte and detection solutions above the surface. Sulfapyridine was used as reference sulfonamide and detected with the immunosensor in buffer and in milk with a limit of detection (IC 90 ) of 0.2 ± 0.1 μg L −1 and 0.5 ± 0.1 μg L −1 , respectively. The analysis time was below 30 min, including regeneration of the sensing surface, with minimum sample preparation required. The reproducibility of the detection was better than 10%. A blind assay allowed identifying milk samples that were contaminated with different sulfonamide antibiotics at or above the maximum residue limits established by the European Union for these compounds (100 μg L −1 ). Thus, the developed immunosensor presents great potential as a generic sensing device for the fast and early detection of food contaminants on the field by non-skilled users.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    38
    References
    47
    Citations
    NaN