The influence of dynamic swash plate vibration on outlet flow ripple in constant power variable-displacement piston pump:

2019 
The vibration of a swash plate is caused by the piston forces and the control actuator acting on the swash plate. An earlier study of the outlet flow ripple of variable-displacement axial piston pumps assumed a fixed swash plate angle; it ignored the influence of swash plate vibration on the outlet flow ripple of the axial piston pump. In this work, a theoretical model of the outlet flow ripple and pressure pulsation was established in a constant power variable-displacement piston pump. The vibration of swash plate, flow leakage, and valve dynamic characteristics are considered in the theoretical model. The computational results of the theoretical model at different external load pressures are verified by comparison with experimental results. The vibration of the swash plate is strongly influenced by both the piston chamber pressure variation and the control actuator mechanism. The study proved the influence of the swash plate vibration on the outlet flow ripple and the pressure pulsation of an axial pist...