Finite element analysis of a hemi-pelvis: the effect of inclusion of cartilage layer on acetabular stresses and strain

2015 
An appropriate method of application of the hip-joint force and stress analysis of the pelvic bone, in particular the acetabulum, is necessary to investigate the changes in load transfer due to implantation and to calculate the reference stimulus for bone remodelling simulations. The purpose of the study is to develop a realistic 3D finite element (FE) model of the hemi-pelvis and to assess stress and strain distribution during a gait cycle. The FE modelling approach of the pelvic bone was based on CT scan data and image segmentation of cortical and cancellous bone boundaries. Application of hip-joint force through an anatomical femoral head having a cartilage layer was found to be more appropriate than a perfectly spherical head, thereby leading to more accurate stress–strain distribution in the acetabulum. Within the acetabulum, equivalent strains varied between 0.1% and 0.7% strain in the cancellous bone. High compressive (15–30 MPa) and low tensile (0–5 MPa) stresses were generated within the acetabul...
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    56
    References
    43
    Citations
    NaN
    KQI
    []