Sensitivity comparison of absorption and grating-based phase tomography of paraffin-embedded human brain tissue

2019 
Advances in high-resolution hard X-ray computed tomography have led to the field of virtual histology to complement histopathological analyses. Phase-contrast modalities have been favored because, for soft tissues, the real part of the refractive index is orders of magnitude greater than the imaginary part. Nevertheless, absorption-contrast measurements of paraffin-embedded tissues have provided exceptionally high contrast combined with a submicron resolution. In this work, we present a quantitative comparison of phase tomography using synchrotron radiation-based X-ray double grating interferometry and conventional synchrotron radiation-based computed tomography in the context of histopathologically relevant paraffin-embedded human brain tissue. We determine the complex refractive index and compare the contrast-to-noise ratio (CNR) of each modality, accounting for the spatial resolution and optimizing the photon energy for absorption tomography. We demonstrate that the CNR in the phase modality is 1.6 tim...