Linking internal resistance with design and operation decisions in microbial electrolysis cells

2019 
Abstract The distribution of internal resistance in most microbial electrolysis cells (MECs) remains unclear, which hinders the optimization and scaling up of the technology. In this study, a method for quantifying the effects of design and operation decisions on internal resistance was applied for the first time to MECs. In typical single chamber MECs with carbon cloth electrodes, the internal resistance was distributed as follows: 210 Ω cm 2 for anode, 77 Ω cm 2 for cathode, and 11 Ω cm 2  M for solution. While varying the spacing of the electrodes ( 2 for anode, 47 Ω cm 2 for cathode, and 5.3 Ω cm 2  M for solution. Adjusting the anode to cathode surface area ratio, to balance the internal resistance distribution, resulted in a significant improvement in performance (47 A/m 2 current density, 3.7 L-H 2 /L-liquid volume/day). These results suggest that the quantification of the internal resistance distribution enables the efficient design and operation of MECs. The parameters obtained in this study were also capable of predicting the performance of MECs from some previous studies, demonstrating the effectiveness of this method.