An In Vitro Comparison of Microleakage between Resilon and Gutta-Percha with a Fluid Filtration Model

2007 
Abstract This investigation compared microleakage of teeth obturated with gutta-percha and teeth obturated with Resilon by using a fluid filtration model. Forty-six human, single-rooted, mandibular premolars were studied. Teeth were randomly assigned to 2 experimental groups of 21 teeth each, designated as group G (gutta-percha) and group R (Resilon). Two control groups, both containing 2 teeth, served as positive and negative controls. Group G, gutta-percha and AH 26 sealer, and group R, Resilon and Epiphany sealer, were obturated by using warm vertical condensation. The specimens were tested for microleakage with an in vitro fluid filtration apparatus at 10 psi at 4 intervals: 1, 7, 30, and 90 days. A two-way repeated measures analysis of variance model with fixed effects for group, time, and group by time interaction was used to analyze microleakage data. This study demonstrated that canals obturated with Resilon and Epiphany sealer leaked statistically less than canals obturated with gutta-percha and AH 26 sealer at day 1 ( P P P P