Implantes cortos. Reporte de 30 implantes: Parte I: oseointegración

2011 
Introduccion: este reporte clinico pretende presentar los resultados obtenidos con un sistema de implantes que modifica el protocolo convencional quirurgico en cuanto a las revoluciones de fresado, no uso de irrigacion, recoleccion del hueso nativo y opciones protesicas como la corona integrada al pilar, la cementacion extraoral y la posicion universal del pilar. En cuanto a su diseno se destaca el uso de implantes cortos, plataforma reducida, aletas laterales, conexion al pilar por cierre friccional y superficie alterada. Metodos: se colocaron treinta implantes Bicon® de seis milimetros de longitud para restauracion de diente unico en veintidos pacientes. Se hizo el protocolo quirurgico de acuerdo con las recomendaciones del fabricante y en dos fases quirurgicas. Se hizo la cirugia de destape de cada implante y se cementaron todas las restauraciones metal-ceramicas. Resultados: se reporta 100% de oseointegracion de los implantes al momento de la cirugia de destape, con ausencia de movilidad o dolor durante  la funcion, ausencia de exudado y normalidad de los tejidos blandos periimplantares; se reporta ausencia de radiolucidez en la evaluacion radiografica. Conclusion: en este estudio podemos concluir que con el protocolo quirurgico modificado y el diseno del implante Bicon® (Bicon™ Dental Implants, Boston, MA) se logro el 100% de exito en la oseointegracion de treinta implantes cortos al momento de la cirugia de destape, con superficie alterada y plataforma reducida, colocados para la restauracion de diente unico en diferentes zonas de la cavidad oral. ABSTRACT. Introduction: the purpose of this clinical report is to present the collected results with an implant system that modifies the classical protocol regarding drilling speed, use of irrigation, native bone collecting and prosthetic options including crown integrated to the abutment, extraoral cementing of the crown and universal position of abutment screw. Regarding implant design, it´s important to highlight the use of short implants, with reduced platform, lateral wings instead of screw threads, abutment connection by means of friction and modified implant surface. Methods: 30 Bicon® implants, all six-mm of length, were placed in order to perform single tooth restorations in 22 patients. The surgical protocol was performed according to indications of the manufacturer in two surgical stages. The implants were uncovered and all metal-ceramic crowns were cemented. Results: the percentage of osseointegration success was 100% at the time of uncovering, without pain or mobility during function, no signs of infection and healthy appearance of peri-implant tissues. There were no radiographic changes at the x-ray evaluation. Conclusion: considering the limitations of this study, it can be concluded that with the modified surgical protocol and the structural design of the Bicon® Implant (Bicon™ Dental Implants, Boston, MA) a 100% osseointegration success was achieved on 30 implants with modified surface and reduced platform, placed in different areas of the oral cavity for single-tooth restoration.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    0
    References
    1
    Citations
    NaN
    KQI
    []