In Situ Passive Sampling of Sediment Porewater Enhanced by Periodic Vibration

2016 
Passive sampling for the measurement of freely dissolved concentrations of organic pollutants in sediment porewater has emerged as a promising approach, but in situ measurements are complicated by slow mass transfer of strongly hydrophobic compounds. The primary resistance to mass transfer arises in the sediment side where a concentration depletion layer develops in the vicinity of the polymeric passive sampling material. The slow mass transfer results in underequilibrated passive sampler measurements that need to be corrected for equilibrium, typically by extrapolation of the loss kinetics of performance reference compounds. Such corrections are prone to large errors, especially when deviation from equilibrium is large. In this research we address the challenge of slow mass transfer by disrupting the external depletion layer around an in situ passive sampler. We report an engineering innovation of adapting low-cost vibration motors for periodically disrupting the depletion layer in a passive sampler depl...