Retrospective Analysis of 77 Hemodialysis Patients Shows No Cases of Steal Syndrome from Graft Taper Reduction.

2020 
Abstract Purpose To review the immediate flow response and incidence of steal syndrome after taper reduction of tapered dialysis grafts. Material and Methods This was a retrospective review of a quality assurance database of all hemodialysis access interventions performed between 2005 and 2017. It identified 77 patients who underwent a taper reduction procedure, involving angioplasty of the arterial limb of the graft and the arterial anastomosis for graft thrombosis/poor flow. A subset of patients underwent 5-, 6-, or 7-mm balloon taper reduction angioplasty coupled with intravascular direct flow measurement (n = 15 with 16 dialysis grafts). A two-tailed Wilcoxon matched-pairs signed-rank test was used to compare pre- and post-taper reduction flows. Mean duration of follow-up was 3.5 years (range, 0–12.5 years). Results Mean access survival after taper reduction was 20.2 months (range, 0.10–94.4 months). Pre- and post-taper reduction access flows (mean Qb ± standard deviation) were 574 ± 315 ml/min and 929 ± 352 ml/min, respectively (P Conclusions Dialysis graft arterial anastomotic taper reduction did not result in the development of steal syndrome within 6 months. In the subset of patients who underwent flow measurements, taper reduction was associated with nearly a 2-fold improvement in access flow, which is a key predictor of access function.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    21
    References
    0
    Citations
    NaN
    KQI
    []