Measurements of escaping alphas in the TFTR DT experiments

1995 
Alpha particle loss to the wall of TFTR has been measured during the initial TFTR DT run period. These measurements were made with the same lost alpha scintillator detector system used previously for DD fusion products, except for a switch of the scintillator material from zinc sulfide (P31) to yttrium aluminate (P46) to insure a linear response up to the maximum alpha flux expected in DT. The alpha loss signals in DT are {approx} 100 times larger than the DD fusion product loss signals, as expected from the neutron rates and the relative sensitivity to DT vs. DD fusion products.