The accuracy of endoscopic ultrasonography for identifying stomach neoplasm before endoscopic submucosal dissection.

2016 
22 Background: The treatment of stomach neoplasm was determined by the identification on of invasion extent and perigastric lymph node through endoscopic ultrasonography (EUS). In this study, we investigated diagnostic accuracy of EUS examination before endoscopic submucosal dissection (ESD). Methods: A retrospective study was conducted to both EUS and ESD for stomach neoplasms that were performed at Seoul Paik Hospital between January 2006 and July 2015. We compared the accuracy of EUS according to the location of lesion, tumor size and ulcer presence or absence on lesion. Results: 49 patients were enrolled in this study; their mean age was 64.14 ± 11.33 years. There were 40 male (81.6%) and 9 female (18.4%) patients. The cases of confined to the mucosa on pathology finding were 41 (83.6%) and involved to submucosal layer(sm) 1 were 3 (6.1%) and sm2 were 2 (4%) and sm3 were 1 (2%) and proper muscle layer were 2 (4%). The cases of lymphatic invasion were 2 (4%). The sensitivity and accuracy of antrum were...