Expanding the number of phthalates monitored in house dust

2016 
ABSTRACTPhthalates have been used as plasticisers for several decades in various industry and consumer products. A method was developed for the determination of 13 not commonly monitored phthalates in household dust. The method was based on solvent extraction using sonication, sample clean-up by solid phase extraction (SPE), and analysis using isotope dilution gas chromatography-tandem mass spectrometry (GC/MS/MS). The method was applied to the analysis of dust samples collected using two vacuum sampling techniques from 38 urban Canadian homes: a sample of fresh or ‘active’ dust (FD) collected by technicians and a composite sample taken from the household vacuum cleaner (HD). Spearman rank correlations between HD and FD samples were significant for six phthalates with median concentrations above their method detection limits (MDLs), suggesting that the HD samples provide comparable results with FD samples. Seven phthalates were detected and quantified in a Canada-wide set of 126 household dust samples, am...