Noninvasive Detection of Myocardial Ischemia From Perfusion Reserve Based on Cardiovascular Magnetic Resonance

2000 
Background—Myocardial perfusion reserve can be noninvasively assessed with cardiovascular MR. In this study, the diagnostic accuracy of this technique for the detection of significant coronary artery stenosis was evaluated. Methods and Results—In 15 patients with single-vessel coronary artery disease and 5 patients without significant coronary artery disease, the signal intensity–time curves of the first pass of a gadolinium-DTPA bolus injected through a central vein catheter were evaluated before and after dipyridamole infusion to validate the technique. A linear fit was used to determine the upslope, and a cutoff value for the differentiation between the myocardium supplied by stenotic and nonstenotic coronary arteries was defined. The diagnostic accuracy was then examined prospectively in 34 patients with coronary artery disease and was compared with coronary angiography. A significant difference in myocardial perfusion reserve between ischemic and normal myocardial segments (1.08±0.23 and 2.33±0.41; P...