In this paper, the partitioned stator flux reversal permanent magnet (PM) (PS-FRPM) machine and the conventional magnetically geared (MG) machine operating in both stator-PM (SPM) and rotor-PM (RPM) modes are comparatively analyzed in terms of electromagnetic performance to provide design guides for an MG machine regarding an SPM- or RPM-type machine and a higher or lower gear ratio machine. It is found that an SPM-type machine is recommended since both PS-FRPM and MG machines operating in SPM modes have a higher phase back-EMF and hence torque than their RPM counterparts, respectively, as a result of a similar phase flux linkage but a higher electric frequency since the iron piece number is larger than the PM pole-pair number. Moreover, a smaller gear ratio machine is preferred from the perspective of a higher power factor and hence a lower inverter power rating, as the conventional MG machines with higher gear ratios suffer from larger flux-leakage, higher synchronous reactance and hence lower power factors, as well as higher iron losses, than the PS-FRPM machines. However, higher gear ratio machines feature lower cogging torques and torque ripples due to the smaller difference between the PM pole-pair number and iron piece number. Both prototypes of PS-FRPM machine operating in SPM mode and MG machine operating in RPM mode are built and tested to verify the finite element predicted results.