Materials compatibility study of 316 stainless steel at the LLL tritium facility

1978 
Stress corrosion tests were conducted on 316 VIM/VAR stainless steel as part of the Tritium Facility's Quality Assurance Program. Initial results under severe conditions indicate earlier-than-expected failure. We are expanding our tests to further examine this problem.